The 2000kVA Three Phase Pad Mounted Transformer from HongweiPower is designed for ground-level power distribution in industrial facilities, commercial developments, utility networks and infrastructure projects. Based on a three-phase oil-immersed transformer configuration, this model features a rated capacity of 2000kVA, an 11kV primary voltage, a 0.4kV secondary voltage and copper windings.
The pad-mounted design integrates the transformer into a protective steel enclosure for outdoor installation on a concrete foundation. Its configuration can be engineered around the project's electrical network, cable connections, protection requirements and available installation space.
HongweiPower supports project-specific configurations covering loop feed or radial feed, dead-front or live-front connections, insulating fluid selection, tap-changing arrangements and protective accessories.
This 2000kVA configuration is developed for project-based requirements within HongweiPower's published 100–2500kVA pad-mounted transformer range. Final enclosure design, electrical parameters and accessory combinations are confirmed through technical review.
Technical Specifications of 2000kVA Pad Mounted Transformer
| Maximum Load Loss and Maximum No-Load Loss of Transformers with a Rated Frequency of 50 Hz |
| |
Grade 1 |
Grade 2 |
| Rated Power |
Maximum Load Loss |
Maximum No-load Loss |
Maximum Load Loss |
Maximum no-load loss |
| kVA |
(Unit: inch) |
(Unit: inch) |
(Unit: inch) |
(Unit: inch) |
| ≤25 |
900 |
70 |
600 |
63 |
| 50 |
1100 |
90 |
750 |
81 |
| 100 |
1750 |
145 |
1250 |
130 |
| 160 |
2350 |
210 |
1750 |
189 |
| 250 |
3250 |
300 |
2350 |
270 |
| 315 |
3900 |
360 |
2800 |
324 |
| 400 |
4600 |
430 |
3250 |
387 |
| 500 |
5500 |
510 |
3900 |
459 |
| 630 |
6500 |
600 |
4600 |
540 |
| 800 |
8400 |
650 |
6000 |
585 |
| 1000 |
10500 |
770 |
7600 |
693 |
| 1250 |
11000 |
950 |
9500 |
855 |
| 1600 |
14000 |
1200 |
12000 |
1080 |
| 2000 |
18000 |
1450 |
15000 |
1305 |
| 2500 |
22000 |
1750 |
18500 |
1575 |
| 3150 |
27500 |
2200 |
23000 |
1980 |
| Note: In some countries, relevant regulations permit higher loss values for transformers that fall outside the applicable scope of this table (such as transformers with wider tap ranges, dual low-voltage windings, or higher voltage levels). |

Pad-Mounted Enclosure and Compartment Design
For the 2000kVA configuration, the enclosure design is evaluated according to cable entry direction, electrical compartment arrangement, public-access safety, maintenance requirements and site conditions.
Protective Steel Enclosure
The cabinet uses a welded steel cover with a three-point latching door and stainless steel hinges.
These structural features support enclosure security and outdoor protection. The cabinet arrangement can be adapted to the project's installation layout and access requirements.
Optional security features include:
-
Three-point door latching.
-
Stainless steel hinges.
-
Kirk-key interlock.
-
Customized door and compartment arrangements.
-
Corrosion-resistant surface treatment.
The Kirk-key interlock can be specified to coordinate access to the low-voltage compartment with the high-voltage switching position.
High-Voltage and Low-Voltage Compartments
The compartment arrangement is an important consideration for utility and industrial procurement.
The high-voltage section accommodates the specified cable connections, bushings, switching and protection components.
The low-voltage section provides the connection interface for downstream distribution equipment.
The following details should be finalized during engineering:
-
HV and LV compartment arrangement.
-
Cable entry and exit direction.
-
Bushing and terminal positions.
-
Required working and maintenance clearance.
-
Grounding terminal locations.
-
Door access and interlocking requirements.
HongweiPower can review project drawings and single-line diagrams to coordinate the cabinet arrangement before manufacturing.
Outdoor Installation and Site Protection
The enclosure is designed for ground-level installation on a concrete pad.
For outdoor projects, the protection design can consider:
-
Rainwater exposure.
-
Humidity and condensation.
-
Dust and airborne contaminants.
-
Coastal salt spray.
-
Chemical corrosion.
-
Unauthorized access.
-
Local ambient temperature.
The required enclosure protection and anti-corrosion treatment should be defined according to the installation environment and applicable project specification.
Loop Feed vs. Radial Feed: Select the Right Connection
Feed configuration affects the transformer connection arrangement and the operating flexibility of the distribution network.
HongweiPower supports loop-feed and radial-feed pad-mounted transformer configurations.
| Configuration |
Connection Arrangement |
Main Advantage |
Typical Project Requirements |
| Radial Feed |
One incoming supply path |
Simpler distribution arrangement |
Individual facilities and straightforward distribution circuits |
| Loop Feed |
Integrated into a loop distribution circuit |
Supports alternative supply routing |
Utility networks, large developments and projects prioritizing supply continuity |
Radial Feed Pad-Mounted Transformer
A radial-feed configuration connects the transformer to one upstream supply path.
It is suitable for projects where the distribution layout uses a straightforward incoming circuit and does not require an alternative supply route through the transformer connection.
The final bushing arrangement, switching equipment and protection coordination are determined by the electrical diagram.
Loop Feed Pad-Mounted Transformer
A loop-feed configuration allows the transformer to be integrated into a distribution loop with alternative supply paths.
This arrangement is useful for utility distribution networks and larger facilities where the network design requires greater supply-routing flexibility.
How to Choose
Choose radial feed when the project uses a single incoming supply path and a simpler connection arrangement.
Consider loop feed when the distribution system requires an alternative power path and switching flexibility.
Dead Front vs. Live Front HV Connection
The high-voltage connection arrangement directly affects electrical safety, cable termination and maintenance access.
HongweiPower supports dead-front and live-front configuration options.
| Comparison |
Dead Front |
Live Front |
| HV Connection |
Fully insulated bushing inserts and elbow connectors |
Exposed high-voltage terminals inside the locked compartment |
| Terminal Protection |
Insulated connection system |
Exposed terminal arrangement when the compartment is open |
| Typical Application |
Public-access and utility distribution installations |
Restricted-access industrial installations and replacement projects |
| Connection Design |
Compatible with specified insulated elbow connections |
Uses the specified exposed-terminal bushing arrangement |
| Selection Basis |
Site safety and utility specifications |
Existing equipment and project connection requirements |
Dead-Front Configuration
Dead-front connections use insulated load-break bushing inserts and compatible elbow connectors.
The insulated arrangement provides an additional barrier around high-voltage connections and is commonly specified for pad-mounted transformers installed in publicly accessible locations.
Live-Front Configuration
Live-front connections use exposed high-voltage terminals within the locked transformer compartment.
This configuration can be selected for projects where the existing distribution system and access restrictions are designed around live-front equipment.
Transformer Protection and Accessory Configuration
Protection devices and accessories should be selected as part of the complete transformer package rather than treated as unrelated optional components.
HongweiPower supports different accessory configurations according to voltage class, connection arrangement and project protection requirements.
| Accessory |
Function |
Configuration |
| HV Bushings |
Connect high-voltage incoming cables |
According to dead-front or live-front design |
| LV Bushings |
Provide low-voltage output connections |
According to rated current and terminal requirements |
| Oil Load-Break Switch |
Switching and isolation functions |
Two-position or four-position options |
| Bay-O-Net Expulsion Fuse |
Overcurrent protection |
Selected according to system protection coordination |
| Current-Limiting Fuse |
Limits fault current under specified conditions |
Partial-range configuration available |
| Surge Arrester |
Helps protect transformer insulation against overvoltage |
Distribution-class or elbow-type options |
| Oil Level Gauge |
Indicates insulating fluid level |
Optional alarm contacts |
| Pressure/Vacuum Gauge |
Monitors internal tank pressure conditions |
According to tank design |
| Dial Thermometer |
Monitors insulating oil temperature |
Optional alarm contacts |
| Off-Circuit Tap Changer |
Adjusts the voltage ratio when de-energized |
According to the required tap range |
| Current Transformers |
Supports metering and monitoring |
Optional metering package |
Protection Configuration for Different Projects
For utility distribution, the protection package should be coordinated with the network's fault-current levels, switching arrangement and operating procedures.
For industrial installations, fuse selection, surge protection and monitoring requirements should reflect the connected loads and electrical protection system.
For renewable energy and BESS projects, the protection and monitoring design should also consider the operating characteristics of the inverter or power conversion system.
Explore additional Power Transformer Accessories from HongweiPower.
Core, Windings and Insulation
Construction
| Component |
Design |
Benefit |
| Windings |
Copper |
Controlled winding resistance, stable electrical and thermal performance at rated load |
| Core |
High-grade silicon steel (high-permeability silicon steel or amorphous alloy on request) |
Lower no-load loss |
| Insulating Fluid |
Mineral oil (standard); FR3 natural ester fluid (optional) |
Electrical insulation and heat transfer |
This pad-mounted 2000kVA, 11kV/0.4kV unit keeps the same core and winding design as our standard oil-immersed model. Only the enclosure and connection arrangement are adapted for ground-level installation. Conductor cross-section, winding layout and cooling are sized to your rated load, ambient temperature and target losses.
Losses and Energy Efficiency
Losses drive the long-term operating cost of a 2000kVA unit, so compare guaranteed no-load and load loss values rather than general efficiency claims.
| Target |
How We Achieve It |
| Lower no-load loss (10%–30% below applicable standard values) |
Better core material, improved lamination, vacuum annealing |
| Lower load loss (8%–25% below applicable standard values) |
Optimized copper cross-section, winding structure and tightness |
| Lower total loss |
Combined core and winding optimization, verified by electromagnetic simulation |
Efficiency levels: GB 20052-2020 Level 1 (highest efficiency) or Level 2 (mainstream), subject to product and project scope.
The percentages above show our optimization capability, not fixed guarantees for every unit. Final loss values and efficiency level are confirmed in the technical datasheet before production.
For more design options, visit HongweiPower Custom Transformer Services.
Protection and Accessories
Protection devices are selected as part of the complete transformer package, according to voltage class, connection arrangement and project protection requirements.
| Accessory |
Function |
Options |
| HV Bushings |
Incoming cable connection |
Dead-front or live-front |
| LV Bushings |
Low-voltage output connection |
Sized to rated current and terminals |
| Oil Load-Break Switch |
Switching and isolation |
Two-position or four-position |
| Bay-O-Net Expulsion Fuse |
Overcurrent protection |
Coordinated with system protection |
| Current-Limiting Fuse |
Limits fault current |
Partial-range available |
| Surge Arrester |
Overvoltage protection |
Distribution-class or elbow-type |
| Oil Level Gauge |
Fluid level indication |
Optional alarm contacts |
| Pressure/Vacuum Gauge |
Tank pressure monitoring |
Per tank design |
| Dial Thermometer |
Oil temperature monitoring |
Optional alarm contacts |
| Off-Circuit Tap Changer |
Voltage ratio adjustment when de-energized |
Per required tap range |
| Current Transformers |
Metering and monitoring |
Optional metering package |
Configuration by application
- Utility distribution: coordinate protection with network fault-current levels, switching arrangement and operating procedures.
- Industrial: match fuse, surge protection and monitoring to connected loads and the plant protection system.
- Renewable energy / BESS: also account for the operating characteristics of the inverter or power conversion system.
The final accessory list, ratings and quantities are confirmed in the approved technical proposal. Browse more Power Transformer Accessories from HongweiPower.
Core, Windings and Insulation
| Component |
Design |
Benefit |
| Windings |
Copper |
Controlled winding resistance, stable electrical and thermal performance at rated load |
| Core |
High-grade silicon steel (high-permeability silicon steel or amorphous alloy on request) |
Lower no-load loss |
| Insulating Fluid |
Mineral oil (standard); FR3 natural ester fluid (optional) |
Electrical insulation and heat transfer |
This pad-mounted 2000kVA, 11kV/0.4kV unit uses the same core and winding design as our standard oil-immersed model. Only the enclosure and connection arrangement are adapted for ground-level installation. Conductor cross-section, winding layout and cooling are sized to your rated load, ambient temperature and target losses.
Losses and Energy Efficiency
Losses drive the long-term operating cost of a 2000kVA unit, so compare guaranteed no-load and load loss values rather than general efficiency claims.
| Target |
How We Achieve It |
| Lower no-load loss (10%–30% below applicable standard values) |
Better core material, improved lamination, vacuum annealing |
| Lower load loss (8%–25% below applicable standard values) |
Optimized copper cross-section, winding structure and tightness |
| Lower total loss |
Combined core and winding optimization, verified by electromagnetic simulation |
Efficiency levels: GB 20052-2020 Level 1 (highest efficiency) or Level 2 (mainstream), subject to product and project scope.
The percentages above show our optimization capability, not fixed guarantees for every unit. Final loss values and efficiency level are confirmed in the technical datasheet before production.
For more design options, visit HongweiPower Custom Transformer Services.
Customized Specifications for 2000kVA Pad-Mounted Transformer
HongweiPower’s pad-mounted range covers 100kVA–2500kVA. This 2000kVA unit is rated 11kV/0.4kV; other ratings can be developed after engineering review.
Electrical Parameters
| Parameter |
Options |
| Primary Voltage (IEC) |
11kV / 22kV / 33kV |
| Secondary Voltage |
400V / 415V |
| Voltage Ratio |
Matched to your grid (current model: 11kV/0.4kV) |
| Tap Range |
Customized to grid requirements |
| Frequency |
Per local network |
| Vector Group, Impedance, BIL, Insulation Levels |
Project-specified |
| Losses and Temperature Rise |
Limits defined in the technical datasheet |
| Grounding |
Per electrical design |
Feed and Connection
| Item |
Options |
| Feed Arrangement |
Loop feed / radial feed |
| HV Connection |
Dead front / live front |
| LV Terminals |
Sized to rated current and busbar |
| Cable Entry and Compartment Layout |
Customized to installation and maintenance needs |
Enclosure
| Item |
Specification |
| Structure |
Welded steel enclosure, dimensions customized to electrical layout |
| Doors |
Customized access layout, three-point latching, stainless steel hinges |
| Safety |
Optional Kirk-key interlock |
| Surface |
Anti-corrosion treatment for site conditions |
| Installation |
Ground-level concrete pad |
Insulating Fluid, Cooling and Regulation
| Item |
Options |
| Insulating Fluid |
Mineral oil / FR3 natural ester |
| Cooling |
ONAN / ONAF / OFAF, per load and ambient temperature |
| Monitoring |
Oil temperature indicator |
| Tap Changer |
Off-circuit (standard); OLTC as a special engineering configuration |
For tap changers, please specify type, number of positions and adjustment range.
Special Environments
| Condition |
Capability |
| High altitude |
≥3,000m |
| High humidity |
RH ≥95% |
| Low / high temperature |
Down to -40°C / up to +55°C |
| Coastal / chemical |
Salt-spray and corrosion protection |
| Dusty sites |
Enhanced sealing |
| Seismic areas |
Structural reinforcement |
| Noise |
Target ≤55dB |
Suitability for this 2000kVA design is confirmed through engineering review. For details, visit HongweiPower Custom Transformer Services.
Applications of 2000kVA Three Phase Pad Mounted Transformer
The 2000kVA pad-mounted transformer is intended for distribution projects requiring high-capacity three-phase power conversion in a ground-level enclosed installation.
Industrial Parks and Manufacturing Facilities
Industrial facilities use transformers to supply production machinery, pumps, compressors, motors and auxiliary electrical systems.
The 2000kVA capacity can be evaluated for industrial distribution networks where the calculated demand and voltage requirements match the transformer configuration.
Project evaluation should include:
-
Connected load and demand factor.
-
Motor starting requirements.
-
Operating load profile.
-
Required low-voltage current capacity.
-
Protection coordination.
-
Installation and maintenance access.
Utility and Underground Distribution Networks
Pad-mounted transformers are commonly used in underground distribution networks where ground-level enclosed equipment is preferred over overhead pole-mounted installations.
The steel cabinet and underground cable connection arrangement support utility and infrastructure projects requiring protected outdoor distribution equipment.
Commercial Complexes and Large Buildings
Commercial developments, shopping centers and large facilities may require ground-level transformers to supply building distribution systems.
The enclosure arrangement, cable connections and protection configuration can be evaluated according to the site's electrical room or outdoor installation layout.
Data Centers and High-Density Computing Facilities
Data centers require coordinated power distribution for IT loads, cooling systems, UPS equipment and auxiliary infrastructure.
For these projects, transformer selection should consider load growth, operating continuity, cooling conditions, harmonic characteristics and the wider power distribution architecture.
Explore HongweiPower Data Center Power Transformer Solutions.
Renewable Energy and Battery Energy Storage Systems
Solar power plants and battery energy storage systems require transformers that match the electrical characteristics of the power conversion equipment and grid connection point.
The transformer voltage ratio, impedance, cooling, protection and monitoring requirements should be evaluated against the system design.
For solar applications, see HongweiPower Grid-Connected Photovoltaic Power Transformer Solutions.
EV Charging Infrastructure
Large EV charging hubs may require high-capacity distribution equipment to supply multiple charging units.
The 2000kVA transformer can be evaluated according to charger quantity, rated power, simultaneous demand, load diversity and grid connection voltage.
IEC Standards and Compliance Requirements
For the 11kV/0.4kV configuration, the applicable IEC 60076 requirements can be specified as part of the technical agreement.
The exact standard editions, design requirements, inspection items and acceptance criteria should be confirmed before manufacturing.
For international projects, buyers should provide their required technical standards and local utility specifications.
Frequently Asked Questions
1. What is the rated voltage of the HongweiPower 2000kVA pad-mounted transformer?
The base configuration is 11kV on the high-voltage side and 0.4kV (400V) on the low-voltage side. Other voltage configurations can be reviewed according to the grid and project requirements.
2. What is the difference between a pad-mounted transformer and a conventional oil-immersed transformer?
A conventional oil-immersed transformer describes the insulation and cooling arrangement. A pad-mounted transformer integrates the oil-immersed transformer into a protective steel enclosure designed for ground-level installation, typically on a concrete pad.
The main differences involve the enclosure, compartment arrangement, bushings, cable connections and protection configuration.
3. Can HongweiPower provide both loop-feed and radial-feed configurations?
Yes. HongweiPower's published pad-mounted transformer range supports loop-feed and radial-feed configurations. The final arrangement depends on the distribution network and the project's single-line diagram.
4. Can I choose between dead-front and live-front connections?
Yes. Both configurations are supported. Dead-front connections use insulated bushing inserts and compatible elbow connectors, while live-front designs use exposed high-voltage terminals within the locked compartment.
5. Does the 2000kVA transformer use copper or aluminum windings?
The base 2000kVA, 11kV/0.4kV product configuration uses copper windings. Other winding material requirements can be evaluated for customized transformer projects.
6. What insulating fluid can be used?
Mineral oil is the standard insulating fluid for the published pad-mounted range. FR3 natural ester fluid is also available for projects requiring specific fire-point or biodegradability characteristics.
7. Can the transformer be customized for lower no-load and load losses?
Yes. HongweiPower's published transformer customization capabilities include no-load loss optimization of 10%–30% and load loss optimization of 8%–25% against applicable standard values.
Request a 2000kVA Pad-Mounted Transformer Quotation
Are you sourcing a 2000kVA Three Phase Pad Mounted Transformer for a utility distribution network, industrial facility, commercial development or renewable energy project?
HongweiPower can review your electrical specifications, installation drawings and accessory requirements to prepare a project-specific technical proposal.
For a customized 2000kVA pad-mounted transformer, send your technical specification or single-line diagram to our team.