Three-phase Oil-immersed Transformer

three phase oil immersed transformer is a core component of medium-voltage power distribution systems. It consists of three sets of primary and secondary windings wound around a silicon steel laminated core, all enclosed within a steel tank filled with transformer mineral oil. The insulating oil serves two simultaneous functions: it provides dielectric insulation between windings and metallic components, and it acts as a thermal transfer medium that dissipates heat generated during operation into the external cooling fins or radiators.

Compared to dry-type (cast-resin) transformers, the three phase oil immersed transformer offers higher overload tolerance, longer service life in outdoor environments, and better cost-effectiveness at medium-to-large capacity ratings (above 315kVA). This makes it the dominant transformer type for outdoor substations, pole-mounted rural distribution, and industrial step-down applications globally.

The key distinguishing feature of Honway Power's three phase oil immersed transformers is the fully-sealed corrugated tank (hermetically sealed) design — eliminating the conservator tank, preventing oil oxidation from atmospheric contact, and removing the need for periodic oil replacement or maintenance inspections.

 

Key Structural Features & Manufacturing Advantages

Fully Sealed Corrugated Oil Tank Our standard three phase oil immersed transformers use a hermetically sealed corrugated tank that expands and contracts elastically with oil thermal variation — eliminating the conservator tank entirely. This prevents atmospheric moisture and oxygen from contacting the transformer oil, virtually eliminating oil aging and oxidation degradation. Result: maintenance-free operation for 15–20+ years under normal service conditions.

High-Grade Silicon Steel Core with Step-Lap Lamination The three-phase core is constructed from high-permeability, cold-rolled grain-oriented silicon steel (CRGO), cut and stacked using step-lap joint technology. This reduces magnetizing current, minimizes no-load losses, and significantly lowers audible noise levels (typically 45–58 dB depending on rating) compared to butt-joint or non-step-lap construction.

Vacuum Pressure Impregnation (VPI) Winding Process Both high-voltage and low-voltage windings are processed through vacuum pressure impregnation (VPI) with insulating varnish after winding. This process eliminates air voids in the insulation system, enhances dielectric strength, and improves moisture resistance — directly reducing the risk of partial discharge failures in service.

Copper or Aluminum Winding — Selectable Copper windings offer lower resistive losses, higher current density, and longer service life, and are recommended for projects where energy efficiency and long-term reliability are priorities. Aluminum windings reduce unit weight and upfront cost, and are suitable for budget-sensitive projects where load factor is lower. Both options are available across the full capacity range.

Proprietary High-Voltage Wire Fixing Technology Honway Power holds a granted utility model patent (Patent No.: ZL 2020 2 1536485.3, CNIPA) for our high-voltage wire fixing device — a design innovation that strengthens winding stability under short-circuit impulse forces, directly improving the transformer's ability to withstand fault current events without internal mechanical deformation.

Radiator Design with Anti-Corrosion Coating External cooling radiators are hot-dip galvanized and coated with anti-corrosion primer before final painting. This provides reliable weather protection for outdoor installations in humid, coastal, or industrial environments where atmospheric corrosion is a service-life concern.

 

Quality Control & Certification

Every three phase oil immersed transformer manufactured at Honway Power's Shijiazhuang facility undergoes a comprehensive routine test protocol before shipment, in full accordance with IEC 60076-1 Clause 10:

Routine Tests Performed on Every Unit:

  • Winding resistance measurement (per IEC 60076-1)
  • Voltage ratio and phase displacement verification
  • Short-circuit impedance and load loss measurement
  • No-load loss and no-load current measurement
  • Induced voltage test (dielectric test)
  • Separate source voltage withstand test (insulation resistance)
  • Oil leakage inspection under pressure

Type Tests Available Upon Request:

  • Temperature rise test (IEC 60076-2)
  • Lightning impulse test (IEC 60076-3)
  • Short-circuit withstand test (IEC 60076-5)
  • Sound level measurement (IEC 60076-10)

Certifications & Recognition:

  • ISO 9001 Quality Management System
  • CE conformity (available for EU-destined units)
  • National High-Tech Enterprise designation (China)
  • Hebei Province "Specialized, Refined, Distinctive & Innovative" SME (Cert. No. SKX202508A2050001)
  • 128+ industry authorized certificates and patents
  • CNIPA Utility Model Patent: ZL 2020 2 1536485.3

Full test reports, factory acceptance test (FAT) documentation, and third-party inspection arrangements (SGS, BV, TÜV) are available upon request.

 

OEM & Customization Capabilities

Beyond our standard S11/S13 catalog, Honway Power Electric handles full custom engineering for three phase oil immersed transformers with non-standard requirements:

Custom Electrical Specifications Any voltage ratio, any kVA rating within production capability, special impedance values, specific vector group (Yd1, Yd11, YNd11, Yy0, etc.), custom tap changer range (DETC or OLTC).

Custom Mechanical & Structural Requirements Special tank dimensions to fit existing substation bays, cable box vs. bushing termination, ground-level vs. pole-mounting hardware, ONAN/ONAF/OFAN cooling configuration, bi-directional radiator layout for restricted installation spaces.

Special Environment Versions High-altitude (1,000m–4,500m) derated designs with enhanced insulation; tropical-climate versions with reinforced anti-corrosion coating; extreme-cold versions (−40°C rated) for northern-climate markets; dust-proof and sealed-bushing versions for mining and industrial environments.

White-Label / OEM Branding Full white-label service for distributors and EPC contractors — custom nameplate, brand painting, and documentation in your company identity.

Lead Times (Standard Production): 50kVA–315kVA standard catalog: 10–15 working days 400kVA–1,250kVA standard catalog: 15–20 working days 1,600kVA–2,500kVA standard catalog: 20–30 working days Custom-engineered units: 30–50 working days

C09.png

 

How to Select the Right Three Phase Oil Immersed Transformer

Procurement engineers evaluating three phase oil immersed transformers should confirm the following parameters before requesting a quotation:

Step 1 — Define Load Requirements Calculate total connected load in kW, apply a demand factor and power factor (typically 0.8–0.9 for industrial loads) to determine required kVA. Apply a 15–20% capacity reserve for future load growth.

Step 2 — Confirm Grid Voltage Levels Identify primary (MV) voltage level: 6kV, 10kV, 11kV, 22kV, 33kV, or 35kV. Identify secondary (LV) distribution voltage required: 380V, 400V, 415V, or 433V.

Step 3 — Specify Installation Environment Indoor or outdoor? Pole-mounted, pad-mounted, or ground-level? Altitude above sea level? Minimum/maximum ambient temperature? Presence of corrosive atmosphere, dust, or explosive gas?

Step 4 — Choose Loss Grade (S11 / S13 / S15) Consider the transformer's annual operating hours and local electricity tariff. For high duty-cycle installations, the long-term energy savings from S13 or S15 units typically outweigh the higher capital cost within 3–5 years.

Step 5 — Confirm Applicable Standard IEC 60076 (most international markets), GB 1094 (China domestic), IEEE C57 (North America), or local national standard? Specify vector group convention (Dyn11 is standard for European-style 3-phase 4-wire distribution; Yyn0 for some Asian markets).

Send us your load calculation sheet or project specification — our engineers will respond within 24 hours with a complete technical proposal and factory-direct quotation.

 

Request a Quote for Your Three Phase Oil Immersed Transformer Project

Fill in your project requirements below, or contact us directly via the channels listed. Our engineering team responds within 24 hours with a technical proposal and factory pricing.

What to include in your enquiry for fastest response:

  • Required kVA rating
  • Primary voltage (MV side)
  • Secondary voltage (LV side)
  • Grid frequency (50Hz or 60Hz)
  • Installation type (outdoor pad / pole / indoor substation)
  • Applicable standard (IEC / IEEE / local)
  • Quantity and delivery location

More +

Close -

12

Get Your Custom Quote

If you need to know more information about transformers, please contact us

-Articles

News & Events

Routine Testing For Oil Immersed Distribution Transformer

Aug.24,2026

Routine Testing For Oil Immersed Distribution Transformer

Routine testing for oil immersed distribution transformers is essential for ensuring their reliability. These transformers are widely used in power distribution networks. However, without proper testing, they can face issues that lead to failures and outages. Tests help identify problems like insulation breakdown and moisture contamination. This article will explore the tests necessary for these

Padmount Transformer Clearance Enclosure Requirements

Aug.24,2026

Padmount Transformer Clearance Enclosure Requirements

Padmount transformer clearance enclosure requirements are vital for safety and functionality. Many homeowners and businesses do not understand these regulations. This lack of awareness can lead to potential hazards. Proper clearance protects both people and equipment from unexpected events. In addition to safety, understanding padmount transformers and their enclosures can enhance performance and

Fire Safety Standards For Pad Mounted Transformer Manufacturers

Aug.24,2026

Fire Safety Standards For Pad Mounted Transformer Manufacturers

Fire safety standards for pad mounted transformer manufacturers are crucial in preventing accidents. These transformers play a vital role in distributing electricity. Proper construction and safety measures can help mitigate risks associated with electrical fires. Following these standards protects both people and property. Many manufacturers must ensure that their products comply with national

Dry Type Transformer Temperature Rise Standards Explained

Aug.24,2026

Dry Type Transformer Temperature Rise Standards Explained

Dry type transformer temperature rise standards are crucial for electrical safety and efficiency. Many users worry about overheating and its impact on the system. Understanding the temperature rise in dry type transformers helps prevent failures and accidents. These transformers provide excellent electrical insulation and operate without liquid coolant. Thus, knowing their temperature limits is

Understanding Core Loss In Grain Oriented Silicon Steel

Aug.24,2026

Understanding Core Loss In Grain Oriented Silicon Steel

Core loss in grain oriented silicon steel can lead to significant energy inefficiencies in electrical devices. This problem affects performance and increases operational costs. Grain oriented silicon steel is crucial in transformers and motors. It is specially designed to reduce core losses. Understanding core losses is vital for manufacturers and users alike. A better grasp of these losses can

Three Phase Oil Cooled Transformer Manufacturer Manufacturing Process

Aug.24,2026

Three Phase Oil Cooled Transformer Manufacturer Manufacturing Process

Three phase oil cooled transformers are crucial to electrical systems. They provide reliable power distribution and ensure equipment operates efficiently. However, many people do not understand the manufacturing process behind these transformers. This lack of knowledge can lead to poor purchasing decisions. Understanding how these transformers are made can help you choose the right manufacturer.

Single Phase Oil Filled Transformer OEM Failure Root Causes

Aug.24,2026

Single Phase Oil Filled Transformer OEM Failure Root Causes

Single phase oil filled transformer OEM failures can lead to significant issues in electrical systems. When these units fail, they can disrupt power distribution and cause safety concerns. Common reasons for failure include poor maintenance, inadequate oil quality, and environmental factors. Recognizing these root causes is essential for preventing future issues. This article explores the main

Charging Station Power Transformer Solution Cost Breakdown

Aug.24,2026

Charging Station Power Transformer Solution Cost Breakdown

The charging station power transformer solution is essential for powering electric vehicle (EV) charging stations. Many businesses face challenges when trying to set up these stations. High costs and understanding transformer needs can be confusing. Additionally, the demand for accessible charging stations is increasing steadily. This article will clarify the costs involved in setting up a

0.292037s