Power Transformer

Honway Power (Shijiazhuang Hongwei Power Transformer Co., Ltd.) is a nationally certified high-tech enterprise specializing in the design, manufacturing, and export of power transformers for industrial, utility, and renewable energy applications. With over 21 years of deep expertise in the power equipment sector, we supply power transformers from 30kVA to 6,300kVA across voltage classes from 0.38kV to 35kV — fully compliant with IEC 60076, GB 1094, and customized to regional grid standards worldwide.

Whether you need a three-phase oil-immersed unit for a substation project, a dry-type power transformer for an indoor data center, or a pad-mounted solution for underground utility distribution, Honway Power Electric delivers engineered reliability backed by 128+ industry certifications and a dedicated R&D team of 150+ professionals.

 

Our Power Transformer Product Range

We manufacture five core types of power transformers, each optimized for specific operating environments and load profiles:

Three-Phase Oil-Immersed Transformer 

The most widely deployed type globally. Our S11/S13-series three-phase oil-immersed power transformers cover 30kVA to 2,500kVA at 10kV, 11kV, and 22kV primary voltage, with IEC 60076-1 compliant fully-sealed corrugated tank construction and copper or aluminum windings available. Suitable for outdoor substation, pole-mounted, and pad-mounted installations.

Single-Phase Oil-Immersed Transformer 

Rated 30kVA to 1,000kVA. Designed for rural electrification, railway power supply, and single-phase industrial loads requiring isolated or step-down voltage conversion. Customizable voltage ratios available upon request.

Dry-Type Transformer (Cast Resin) 

Rated 30kVA to 6,000kVA, voltage class 0.38kV to 12kV. Epoxy-resin vacuum-cast windings with F/H class insulation — zero risk of oil leakage, ideal for indoor environments including data centers, hospitals, high-rise buildings, and fire-sensitive industrial facilities. Compliant with IEC 60076-11.

Pad-Mounted Transformer 

Tamper-resistant, weather-sealed enclosure design for below-grade or ground-level installation in residential subdivisions, commercial campuses, and underground distribution networks. Available in single-phase and three-phase configurations, 15kVA to 2,500kVA.

European-Style Transformer 

Compact integrated substation design (transformer + switchgear + metering in one enclosure). Preferred for European grid infrastructure projects and export markets requiring EN 50588 compliance.

 

Why Buyers Choose Honway Power as Their Power Transformer Supplier

21+ Years of Transformer Manufacturing Experience 

Founded on deep roots in China's Hebei power equipment manufacturing cluster, Honway Power has been delivering power transformers to domestic utilities and international buyers since the early 2000s. Our institutional knowledge spans raw material sourcing, silicon steel core lamination, vacuum-pressure impregnation, and full type-test protocol.

Proprietary R&D with Granted Patents 

Our independently developed High-Voltage Wire Fixing Device (Patent No.: ZL 2020 2 1536485.3, granted by CNIPA) is one of 128+ authorized industry certificates held by the company. Our R&D team — led by engineers with 20+ years of hands-on transformer design experience — continuously advances core efficiency, noise reduction, and load adaptability in our power transformer product lines.

Hebei Science & Technology SME Designation 

Recognized by the Hebei provincial government as a "Specialized, Refined, Distinctive, and Innovative" SME and a Science and Technology-based enterprise (Certification No. SKX202508A2050001), Honway Power operates to a higher technical standard than typical trading companies or assembly-only factories.

20,000 m² Production Base, 150+ Person Team 

Our dedicated manufacturing facility enables consistent batch output with full in-process quality control. Production capacity covers standard catalog models for fast delivery and full-custom engineering for special operating conditions (high altitude, extreme cold, corrosive environments, mining, offshore).

IEC 60076 Compliant Across the Full Range 

Every power transformer we ship undergoes routine tests per IEC 60076-1, including ratio measurement, short-circuit impedance, no-load loss, load loss, insulation resistance, and induced overvoltage tests. Type test reports available upon request.

C09.png

 

OEM & Custom Power Transformer Solutions

Standard catalog models ship fast. But many of our clients come to us precisely because their project requires something outside the catalog. Honway Poweraccepts full OEM and custom orders with the following flexibility:

  • Custom Capacity: Any kVA rating within 30kVA–6,300kVA range; larger capacity on application
  • Custom Voltage Ratio: Any combination of primary/secondary voltage supported by your regional grid standard
  • Custom Structure: Tank dimensions, conservator vs. fully-sealed, radiator count, bushing type, OLTC / DETC tap changer
  • Custom Cooling: ONAN, ONAF, OFAN or forced-cooling upgrades
  • Custom Certifications: We support third-party type testing and documentation for CE, KEMA, GOST, and other market-specific approvals
  • Custom Nameplate & Branding: White-label / OEM branding for distributors and project contractors

Standard Lead Times: Distribution transformers (catalog): 15–20 working days Dry-type transformers (catalog): 10–15 working days Custom-engineered units: 30–60 working days depending on complexity

Send us your technical datasheet, single-line diagram, or project specification, and our engineering team will respond with a detailed quotation within 24 hours.

 

Request a Quotation for Your Power Transformer Project

Tell us your project requirements and we'll provide a detailed engineering proposal and competitive factory price within 24 hours.

More +

Close -

Get Your Custom Quote

If you need to know more information about transformers, please contact us

-Articles

News & Events

Insulation Resistance Sourcing Single Phase Oil Filled Transformer OEM

Oct.06,2026

Insulation Resistance Sourcing Single Phase Oil Filled Transformer OEM

Insulation resistance sourcing single phase oil filled transformer OEM can be a challenging task. Many businesses struggle to find reliable suppliers. Poor insulation resistance can lead to transformer failures, affecting operations. It is crucial to choose the right manufacturer to avoid these issues. In this article, we will explore the importance of insulation resistance. We will also look at

Dry Type Transformer VPI vs Cast Resin Technology

Oct.06,2026

Dry Type Transformer VPI vs Cast Resin Technology

Dry type transformers are electrical devices used for voltage conversion without using liquid cooling methods, making them suitable for various environments. They come primarily in two technologies: VPI (Vacuum Pressure Impregnated) and cast resin.

Liquid Cooled Charging Station Power Transformer Solution

Oct.05,2026

Liquid Cooled Charging Station Power Transformer Solution

In the evolving world of electric vehicles (EVs), the demand for efficient charging infrastructure is critical. Liquid cooled charging station power transformers provide innovative solutions to manage high power demands while ensuring reliable operation. With advancements in technology, these transformers offer enhanced cooling performance, reduce energy losses, and improve overall operational

Application Checklist For 30~1000kva Singlephase Transformer

Oct.05,2026

Application Checklist For 30~1000kva Singlephase Transformer

The application checklist for a 30~1000kva single-phase transformer is essential for electrical engineers, facility managers, and project stakeholders responsible for power distribution solutions. Having a reliable power source is critical; without it, facilities can face extreme downtime, noise from systems, increased operational costs, and potential equipment damage. This piece serves to guide

Anti Islanding In Grid Connected Photovoltaic Power Transformers Solution

Oct.02,2026

Anti Islanding In Grid Connected Photovoltaic Power Transformers Solution

As the demand for renewable energy sources grows, the efficiency and safety of photovoltaic (PV) systems, particularly in grid-connected applications, have become critical. A significant concern is the phenomenon known as islanding—when a portion of the grid continues to operate independently despite the main grid being down. Implementing effective anti-islanding measures in photovoltaic power

Oil Type Distribution Transformer Dissolved Gas Analysis DGA

Oct.02,2026

Oil Type Distribution Transformer Dissolved Gas Analysis DGA

The oil type distribution transformer dissolved gas analysis DGA is crucial for monitoring the health of electrical equipment. Every transformer has insulating oil that helps maintain its efficiency. Over time, gases can form in this oil due to various conditions, leading to potential failures. Understanding oil analysis assists in detecting these problems early and enhances safety. Proper DGA

Protection Scheme For 12.47 kV 208 V Pad Mounted Transformer

Oct.01,2026

Protection Scheme For 12.47 kV 208 V Pad Mounted Transformer

Ensuring the optimal performance and longevity of a 12.47 kV 208 V pad mounted transformer is crucial for industrial applications. The right protection scheme, which includes various safety mechanisms and monitoring systems, can prevent costly downtime and equipment damage. This article outlines effective protection strategies, addressing common user pain points while providing a clear

Sourcing Bushings From Power Transformer Accessories Supplier

Oct.01,2026

Sourcing Bushings From Power Transformer Accessories Supplier

Sourcing bushings from a power transformer accessories supplier is crucial for maintaining electrical systems. Bushings are key components that connect different voltage levels. They help in safety and reliability. If you need to select the right bushings, issues can arise. Poor quality can lead to failures and costly repairs. Understanding your options can spark your interest in reliable supply