Hongweipower Power manufactures single-phase oil-immersed distribution transformers for overhead power distribution, rural electrification, residential and commercial power supply, and utility projects. The product series features a CRGO silicon steel core, oil-immersed insulation and a sealed corrugated steel tank, with customized voltage ratios, tap configurations, protection devices and installation arrangements available for different distribution networks.
10kVA Single Phase Oil Filled Transformer Specifications
| Parameters of Single-Phase Overhead Pole-Mounted Distribution Transformers |
| Rated Capacity (kVA) |
Rated Voltage |
Losses (W) |
| H.V. (kV) |
Tap Range |
Length |
No-load |
Load |
| 3 |
33
30
17.321
11.547
13.8
7.967
7.62
6.35 |
±2×2.5% |
120
220
240
480 |
9 |
45 |
| 5 |
19 |
75 |
| 10 |
36 |
120 |
| 15 |
50 |
195 |
| 25 |
80 |
290 |
| 37.5 |
105 |
360 |
| 50 |
135 |
500 |
| 75 |
190 |
650 |
| 100 |
210 |
850 |
| 167 |
350 |
1410 |
| 250 |
500 |
2000 |
| 333 |
650 |
2500 |

50Hz and 60Hz Power Frequency
Hongweipower Power supplies transformer configurations for 50Hz and 60Hz distribution networks. The rated frequency is considered together with the primary voltage, secondary voltage, core design and insulation requirements.
50Hz Transformer Configuration
Suitable for distribution networks operating at 50Hz. The transformer is designed around the specified rated voltage and electrical operating conditions.
60Hz Transformer Configuration
Designed for 60Hz power systems, with the corresponding electromagnetic design and rated electrical parameters.
Both frequency configurations can be incorporated into customized single-phase transformer specifications for different export markets.
Low No-Load Loss and Load Loss Performance
Transformer losses affect electricity consumption throughout the equipment's operating life. For distribution networks with long operating hours, selecting appropriate no-load and load loss values helps control energy costs and improve overall system efficiency.
No-Load Loss (P0): 36W for the 10kVA Model
No-load loss mainly originates from the transformer core when the unit is energized. Hongweipower Power uses CRGO grain-oriented silicon steel with step-lap core construction to improve magnetic flux distribution and reduce core losses.
The core lamination and joint arrangement are important factors in controlling excitation losses and transformer operating noise.
Load Loss (Pk): 120W for the 10kVA Model
Load loss is mainly associated with winding resistance and other load-dependent losses. Winding conductor dimensions, winding arrangement and electrical design influence the resulting load loss.
Hongweipower optimizes core materials and winding structures according to specified electrical performance requirements.
Transformer Energy Efficiency Options
For projects with defined energy-efficiency requirements, the transformer can be designed around specified maximum no-load loss and load loss values.
The technical configuration can incorporate:
-
Low-loss CRGO silicon steel core construction
-
Optimized core lamination and magnetic circuit
-
Winding structure optimization
-
Project-specific loss requirements
-
Factory no-load loss and load loss testing
Hongweipower provides loss measurement as part of its factory inspection process, allowing the supplied transformer to be evaluated against the agreed technical specifications.
Tap Changer and Voltage Regulation Configurations
Voltage fluctuations in distribution networks can affect the quality of the supplied electrical power. A suitable tap changer configuration helps adjust the transformer voltage ratio to accommodate variations in the incoming supply.
Standard HV Tap Range: ±2 × 2.5%
The published single-phase transformer series includes a high-voltage tap range of ±2 × 2.5%, providing voltage adjustment around the rated primary voltage.
The tap arrangement is suitable for projects requiring adjustment to the incoming distribution voltage.
Off-Circuit Tap Changer (DETC)
An off-circuit tap changer adjusts the winding connection while the transformer is de-energized. It provides a practical voltage adjustment arrangement for distribution applications where voltage changes can be made during planned shutdowns.
On-Load Tap Changer (OLTC)
For applications requiring voltage regulation without interrupting the power supply, an on-load tap changer can be incorporated into a customized transformer design.
OLTC configurations can be designed with corresponding tap positions, operating mechanisms and control accessories according to the required voltage regulation range.
Hongweipower also offers customized tap range and electrical configurations for projects with special grid voltage requirements.
IEC Standards, CE Compliance and Factory Testing
Hongweipower manufactures single-phase oil-immersed transformers with reference to the IEC 60076 series and provides factory inspection documentation for supplied units.
CE Conformity for European Markets
CE conformity documentation is available for EU-destined units. Hongweipower provides product-related compliance documentation according to the applicable product configuration and destination market.
Additional Type Testing
The following type tests are available upon request:
-
Temperature Rise Test — IEC 60076-2
-
Lightning Impulse Withstand Test — IEC 60076-3
-
Short-Circuit Withstand Test — IEC 60076-5
-
Sound Level Measurement — IEC 60076-10
Third-party witnessed testing through SGS, Bureau Veritas and TÜV Rheinland can also be arranged in advance.
Outdoor Pole-Mounted Installation and Applications
Single-phase oil-immersed distribution transformers are widely used in overhead distribution systems where single-phase power is required at residential, commercial and rural supply points.
Rural Electrification
Pole-mounted transformers provide local voltage conversion for rural distribution networks with dispersed residential loads. Their outdoor installation arrangement is suitable for overhead power lines serving remote communities.
Residential Power Distribution
Single-phase transformers supply residential distribution systems where the incoming medium-voltage network and required low-voltage output use a single-phase configuration.
Agricultural and Irrigation Power Supply
Applications include agricultural facilities, irrigation equipment and remote power supply points connected to single-phase overhead distribution networks.
Small Commercial Facilities
The transformer series can serve small commercial distribution loads where the required capacity and electrical configuration match the selected model.
Utility Distribution Projects
For utility and EPC projects, the transformer can be supplied with customized voltage ratios, tap configurations, protection devices and technical documentation according to the project specification.
Customized Single-Phase Transformer Manufacturing
Hongweipower provides customized transformer design for different grid standards, installation requirements and operating environments.
| Customization Item |
Available Configuration |
| Rated Capacity |
Multiple kVA ratings and customized capacity |
| Primary Voltage |
Customized high-voltage levels |
| Secondary Voltage |
Customized low-voltage output |
| Frequency |
50Hz / 60Hz |
| Short-Circuit Impedance |
Project-specific impedance |
| Tap Changer |
HV tap adjustment and optional OLTC design |
| Connection Group |
Customized connection arrangement |
| Insulation |
Customized insulation class and dielectric design |
| Tank Structure |
Hermetically sealed, corrugated or conservator-type |
| Installation |
Pole-mounted, pad-mounted or prefabricated substation arrangements |
| Cooling |
Natural or forced cooling configurations |
| Protection |
Fuses, surge arresters, relays and monitoring devices |
| Surface Treatment |
Anti-corrosion coating and stainless-steel enclosure options |
| Branding |
OEM nameplate, appearance and packaging |
For high-altitude, low-temperature, coastal or corrosive environments, customized insulation and protection solutions are available.
Hongweipower also provides OEM/ODM services for distributors, electrical equipment suppliers and project contractors, including customized nameplates, product coatings and packaging.
Learn more about Power Custom Transformer Manufacturing.
Technical Documents and Transformer Supply
Each transformer order is supported by factory inspection and the technical documentation associated with the agreed product specification.
Available documentation and inspection services include:
-
Transformer Technical Datasheet
-
Electrical Rating and Nameplate Information
-
Voltage Ratio and Connection Test Records
-
No-Load Loss and Load Loss Test Records
-
Insulation and Withstand Voltage Test Records
-
Factory Inspection Report
-
Applicable CE Conformity Documentation
-
Additional Type Test Documentation
-
Third-Party Inspection Arrangements
For customized orders, technical drawings and electrical configurations can be developed according to the agreed project requirements.
Visit Power Technical Support for information about product testing and technical services.
Request a Quote for a Single-Phase Oil-Immersed Transformer
Hongweipower supplies single-phase oil-immersed distribution transformers for utility distributors, electrical contractors, EPC companies and overseas power equipment buyers.
Send your technical specifications, utility requirements or project drawings to receive a transformer proposal tailored to your distribution system.
Contact Power for a Transformer Quotation