The 3150kVA Three-Phase Oil-Immersed Power Transformer from Hongweipower is designed for high-capacity industrial power distribution, mining facilities and regional distribution substations. With a 22kV primary voltage and 400V secondary voltage, this model provides step-down power conversion for large electrical loads.
The transformer features full copper windings, an oil-immersed insulation and cooling system, and a fully sealed tank structure. Its electrical specifications, cooling configuration, voltage regulation and energy efficiency can be customized according to project requirements.
Designed with reference to applicable IEC 60076 requirements,Hongweipower's transformer solutions support industrial facilities, engineering contractors and power distribution projects requiring specific electrical and installation configurations.
Technical Specifications of 3150kVA Transformer
| Maximum Load Loss and Maximum No-Load Loss of Transformers with a Rated Frequency of 50 Hz |
| |
Grade 1 |
Grade 2 |
| Rated Power |
Maximum Load Loss |
Maximum No-load Loss |
Maximum Load Loss |
Maximum no-load loss |
| kVA |
(Unit: inch) |
(Unit: inch) |
(Unit: inch) |
(Unit: inch) |
| ≤25 |
900 |
70 |
600 |
63 |
| 50 |
1100 |
90 |
750 |
81 |
| 100 |
1750 |
145 |
1250 |
130 |
| 160 |
2350 |
210 |
1750 |
189 |
| 250 |
3250 |
300 |
2350 |
270 |
| 315 |
3900 |
360 |
2800 |
324 |
| 400 |
4600 |
430 |
3250 |
387 |
| 500 |
5500 |
510 |
3900 |
459 |
| 630 |
6500 |
600 |
4600 |
540 |
| 800 |
8400 |
650 |
6000 |
585 |
| 1000 |
10500 |
770 |
7600 |
693 |
| 1250 |
11000 |
950 |
9500 |
855 |
| 1600 |
14000 |
1200 |
12000 |
1080 |
| 2000 |
18000 |
1450 |
15000 |
1305 |
| 2500 |
22000 |
1750 |
18500 |
1575 |
| 3150 |
27500 |
2200 |
23000 |
1980 |
| Note: In some countries, relevant regulations permit higher loss values for transformers that fall outside the applicable scope of this table (such as transformers with wider tap ranges, dual low-voltage windings, or higher voltage levels). |
Construction and Energy Efficiency
Core Construction
| Component |
Design |
Benefit |
| Windings |
Full copper (aluminum available on request) |
Efficient current transmission, lower load loss |
| Core |
High-permeability CRGO silicon steel, step-lap lamination, vacuum annealed |
Lower no-load loss and operating noise |
| Oil Tank |
Fully sealed corrugated tank |
Limits moisture and oxygen contact with the oil; minimal routine maintenance |
| HV Winding Support |
Patented high-voltage wire fixing device |
Stronger winding stability under short-circuit forces |
| Radiators |
Hot-dip galvanized with anti-corrosion coating |
Suited to humid, coastal and industrial outdoor sites |
Tank structure, radiator layout and external dimensions can be adapted to your installation conditions.
Loss Performance
A 3150kVA unit runs continuously, so losses drive long-term electricity cost. We reduce them at the source:
- No-load loss: 10%–30% below applicable standard values, through better core material (silicon steel or amorphous alloy), optimized lamination and joints, and vacuum annealing.
- Load loss: 8%–25% below applicable standard values, through optimized conductor cross-section, winding arrangement and connection quality.
Both are refined with electromagnetic simulation.
Choosing an Efficiency Level (GB 20052-2020)
| Level |
Best For |
| Level 1 |
Projects that prioritize the lowest operating losses |
| Level 2 |
Projects balancing investment and energy consumption |
Final loss values and efficiency level are confirmed in the approved datasheet. For project-specific requirements, visit Customized Transformer Services.
Customized Specifications for 3150kVA Power Transformer
Hongweipower customizes three-phase oil-immersed transformers from 30kVA to 10,000kVA. This model is rated 22kV/400V; other ratios can be configured to your grid.
1. Electrical Parameters
| Parameter |
Options |
| Rated Capacity |
30kVA–10,000kVA per unit |
| Primary Voltage |
10kV / 20kV / 35kV standard; 60kV / 66kV on request |
| Secondary Voltage |
400V / 415V / project-specified |
| Frequency |
50Hz / 60Hz |
| Vector Group |
Dyn11 / Yyn0 / other |
| Short-Circuit Impedance |
Project-specified |
| No-Load Loss |
10%–30% below applicable standard values |
| Load Loss |
8%–25% below applicable standard values |
| Efficiency Level |
GB 20052-2020 Level 1 / Level 2 |
| Noise |
Target ≤55dB |
| Parallel Operation |
Supported |
2. Voltage Regulation
| Type |
Use When |
| DETC (de-energized) |
Fixed tap settings are sufficient |
| OLTC (on-load) |
Voltage must be regulated during operation; motorized, local or remote control available |
Tap positions and adjustment range are set according to your grid voltage variation.
3. Cooling and Construction
| Item |
Options |
| Cooling |
ONAN / ONAF / OFAN / OFAF, selected by load profile and ambient temperature |
| Core |
CRGO silicon steel / amorphous alloy |
| Winding |
Copper / aluminum |
| Tank |
Fully sealed or non-sealed; corrugated or project-specific |
| Radiators and Dimensions |
Customized layout, length, width and height |
| Surface Treatment |
Anti-corrosion and coastal protection |
| Installation |
Indoor / outdoor |
4. Special Environments
| Condition |
Capability |
| High altitude |
≥3,000m |
| High humidity |
RH ≥95% |
| Low temperature |
Down to -40°C |
| Coastal / chemical |
Salt-spray and corrosion protection |
| Dusty sites |
Enhanced sealing |
| Seismic areas |
Customized reinforcement |
Insulation, cooling, protection and structure are adjusted accordingly during engineering design.
For details, visit Custom Transformer Services.
Transformer Accessories and Protection Configuration
A 3150kVA transformer requires appropriate electrical connections, monitoring devices and protective components to support safe operation and maintenance.
Hongweipower provides accessory configuration according to project specifications.
| Accessory |
Function |
| HV Bushings |
High-voltage electrical connection |
| LV Bushings |
Low-voltage electrical connection |
| Tap Changer |
Voltage ratio adjustment |
| Oil Level Indicator |
Monitoring insulating oil level |
| Oil Temperature Indicator |
Monitoring oil temperature |
| Winding Temperature Indicator |
Monitoring winding temperature |
| Pressure Relief Device |
Releasing excessive internal pressure |
| Gas Relay (Buchholz Relay) |
Detecting gas accumulation and oil-flow-related faults in applicable designs |
| Earthing Terminals |
Transformer grounding connection |
| Oil Drain and Sampling Valve |
Oil drainage and sampling |
| Cooling Fans |
Forced-air cooling for applicable configurations |
| Protective Relays |
Electrical protection according to project design |
| Intelligent Monitoring Module |
Temperature, voltage and current monitoring where specified |
The final accessory list is confirmed in the approved technical specification and commercial quotation.
Applications of 3150kVA 22kV/400V Transformer
The 3150kVA three-phase oil-immersed transformer is intended for power distribution projects requiring high-capacity voltage conversion from 22kV to 400V.
Mining and Mineral Processing Facilities
Mining facilities often operate crushers, conveyors, pumps, ventilation systems and other high-power equipment.
A 3150kVA transformer can be considered for mining distribution systems where the connected load, motor starting conditions and voltage requirements match the proposed configuration.
Large Manufacturing Plants
Large industrial facilities require power distribution for production lines, motors, processing equipment and auxiliary systems.
The 22kV/400V configuration can support industrial power distribution when the incoming grid and downstream equipment match these voltage ratings.
Regional Distribution Substations
Regional distribution projects use power transformers to convert medium-voltage electricity into low-voltage power for downstream distribution.
The 3150kVA rating, voltage ratio, impedance and protection arrangement should be selected according to the substation's electrical design.
Commercial and Industrial Centers
Large commercial centers and industrial parks require coordinated power distribution for multiple buildings, equipment rooms and supporting infrastructure.
Transformer selection should consider the total demand, load diversity, future expansion and available installation space.
Power and Renewable Energy Infrastructure
For renewable energy and infrastructure projects, transformer configuration must match the electrical connection point, power flow direction and grid requirements.
Hongweipower also provides customized transformer and power distribution solutions for different industrial and energy applications.
Explore our Power Transformer Solutions for additional project configurations.
Factory Testing and Inspection
Quality inspection is carried out throughout the manufacturing process, from raw material procurement to final product release.
For the 3150kVA transformer, the agreed inspection scope can cover the following items.
Raw Material Inspection
-
Silicon steel material inspection.
-
Copper conductor inspection.
-
Insulating material inspection.
-
Transformer oil quality inspection.
-
Accessory and protection-device inspection.
In-Process Inspection
-
Core lamination and stacking inspection.
-
Winding DC resistance measurement.
-
Insulation resistance inspection.
-
Coil arrangement and fastening inspection.
-
Vacuum drying process monitoring.
-
Tank welding and sealing inspection.
IEC Standards and Project Documentation
For international transformer procurement, compliance requirements should be confirmed according to the destination market and project specification.
Hongweipower evaluates the applicable requirements of IEC 60076 and the GB/T 1094 series for transformer design, manufacturing and testing.
Installation, Dimensions and Export Delivery
A 3150kVA transformer requires careful coordination between electrical design, civil construction and transportation planning.
Customized Dimensions and Foundation Requirements
Hongweipower can evaluate the overall transformer dimensions according to:
-
Available installation length, width and height.
-
Foundation dimensions and load-bearing requirements.
-
HV and LV terminal positions.
-
Cable or busbar connection direction.
-
Radiator clearance and cooling airflow.
-
Lifting and maintenance access.
-
Oil drainage and containment requirements where applicable.
Transportation and Lifting Arrangements
For large-capacity transformer delivery, buyers should confirm:
-
Shipping weight and operating weight.
-
Overall transportation dimensions.
-
Loading and unloading arrangements.
-
Lifting points and equipment requirements.
-
Transportation route restrictions.
-
Export packaging requirements.
-
Site unloading and installation conditions.
Hongweipower's published customization service supports professional logistics arrangements, large transport vehicles, lifting equipment, insurance coverage and on-site unloading.
Frequently Asked Questions
1. What is the primary and secondary voltage of this 3150kVA transformer?
This model is configured with a 22kV primary voltage and a 400V secondary voltage. Other voltage ratios can be evaluated according to the local grid and project requirements.
2. What is the rated current of a 3150kVA 22kV/400V transformer?
For a three-phase 3150kVA transformer, the theoretical rated current is approximately 82.7A on the 22kV side and 4,547A on the 400V side.
3. Why choose copper windings for a 3150kVA transformer?
Copper has high electrical conductivity and supports low winding resistance. Copper winding configurations are suitable for projects prioritizing electrical performance, loss control and long-term operation.
Hongweipower also offers aluminum winding configurations for other project requirements.
4. Can the transformer operate at both 50Hz and 60Hz?
Hongweipower supports 50Hz and 60Hz transformer configurations. The required frequency must be specified before manufacturing because frequency affects magnetic flux density, core design and electrical performance.
5. Can Hongweipower customize the no-load loss and load loss?
Yes. Hongweipower provides no-load loss optimization of 10%–30% and load loss optimization of 8%–25% against applicable standard values.
6. Can the 3150kVA transformer use an OLTC tap changer?
Yes. Hongweipower supports DETC and OLTC configurations. OLTC can be evaluated for projects requiring voltage regulation while the transformer remains energized.