The 1250kVA Three-Phase Oil-Immersed Distribution Transformer from Hongweipower Power is designed for medium-voltage power distribution systems requiring 22kV input and 0.4kV output. This model provides a rated capacity of 1250kVA for industrial plants, distribution substations, regional power stations and large power distribution centers.
Designed with reference to IEC 60076, this oil-immersed transformer supports project-specific electrical configurations, energy efficiency requirements and installation conditions. Hongweipower Power provides transformer manufacturing, technical evaluation and customized engineering services to match different grid requirements.
For buyers comparing different capacity and voltage configurations, explore our Three-Phase Oil-Immersed Transformer Range.
Technical Specifications of the 1250kVA Transforme
| Maximum Load Loss and Maximum No-Load Loss of Transformers with a Rated Frequency of 50 Hz |
| |
Grade 1 |
Grade 2 |
| Rated Power |
Maximum Load Loss |
Maximum No-load Loss |
Maximum Load Loss |
Maximum no-load loss |
| kVA |
(Unit: inch) |
(Unit: inch) |
(Unit: inch) |
(Unit: inch) |
| ≤25 |
900 |
70 |
600 |
63 |
| 50 |
1100 |
90 |
750 |
81 |
| 100 |
1750 |
145 |
1250 |
130 |
| 160 |
2350 |
210 |
1750 |
189 |
| 250 |
3250 |
300 |
2350 |
270 |
| 315 |
3900 |
360 |
2800 |
324 |
| 400 |
4600 |
430 |
3250 |
387 |
| 500 |
5500 |
510 |
3900 |
459 |
| 630 |
6500 |
600 |
4600 |
540 |
| 800 |
8400 |
650 |
6000 |
585 |
| 1000 |
10500 |
770 |
7600 |
693 |
| 1250 |
11000 |
950 |
9500 |
855 |
| 1600 |
14000 |
1200 |
12000 |
1080 |
| 2000 |
18000 |
1450 |
15000 |
1305 |
| 2500 |
22000 |
1750 |
18500 |
1575 |
| 3150 |
27500 |
2200 |
23000 |
1980 |
|
Note: In some countries, relevant regulations permit higher loss values for transformers that fall outside the applicable scope of this table (such as transformers with wider tap ranges, dual low-voltage windings, or higher voltage levels).
|
Transformer Construction and Configuration Options
The performance of a 1250kVA oil-immersed transformer depends on its core, windings, insulation system, oil tank and cooling arrangement. These components should be evaluated together when confirming the final project configuration.
1. Transformer Core
Hongweipower's three-phase oil-immersed transformer range uses high-grade cold-rolled grain-oriented silicon steel (CRGO) with step-lap core lamination technology.
The core design and lamination process are important for controlling magnetizing current, no-load loss and operating noise.
2. Copper and Aluminum Windings
Hongweipower provides copper and aluminum winding options according to the selected transformer model and project requirements.
| Winding Material |
Procurement Considerations |
| Copper Winding |
Suitable for projects prioritizing electrical conductivity, winding resistance and long-term operating performance |
| Aluminum Winding |
An alternative for projects evaluating conductor cost, weight and overall equipment budget |
The final winding material, conductor specifications and winding arrangement should be confirmed in the technical proposal.
3. Oil Tank Structure
Hongweipower's standard three-phase oil-immersed transformer range identifies fully sealed corrugated oil tanks as a standard structural configuration.
The corrugated tank accommodates changes in insulating oil volume during temperature variations while providing an enclosed environment for the core, windings and insulating oil.
Other tank structures, including sealed, non-sealed and conservator configurations, can be evaluated according to the selected product and project requirements.
4. Cooling and Tap-Changer Configuration
Cooling and voltage regulation should match the transformer rating, grid voltage variation and operating conditions.
Available configurations across Hongweipower's transformer range include:
-
ONAN – Oil Natural Air Natural.
-
ONAF – Oil Natural Air Forced.
-
OFAF – Oil Forced Air Forced.
Tap-changer options include:
The cooling method, tap changer type and adjustment range for the 1250kVA unit are confirmed during engineering review.
5. Protection and Monitoring Accessories
Depending on the selected design, optional transformer accessories can include:
-
Pressure Relief Valve.
-
Gas Relay.
-
Oil Temperature Indicator.
-
Winding Temperature Indicator.
-
Cooling Fans.
-
Protective Relays.
-
Intelligent Monitoring Modules.
The actual accessory list is determined by the approved design and project protection requirements.
Applications of the 1250kVA 22kV/0.4kV Distribution Transformer
A 1250kVA three-phase transformer with a 22kV/0.4kV voltage ratio can serve distribution projects where the incoming medium-voltage network and downstream low-voltage system match the specified configuration.
Industrial Manufacturing Plants
Manufacturing facilities require stable power distribution for production equipment, motors, processing machinery and auxiliary systems.
The 1250kVA rating provides a defined capacity for industrial distribution projects. Final suitability should be checked against the plant's maximum demand, load profile, starting currents and future expansion plans.
Distribution Substations
Distribution substations use transformers to convert incoming medium voltage into a lower voltage for downstream distribution.
The 22kV/0.4kV configuration is suitable for projects designed around these voltage levels, subject to the local network specification and substation design.
Regional Power Stations and Distribution Centers
Regional distribution facilities require transformer equipment that matches the planned network voltage, load demand and protection arrangements.
A 1250kVA transformer can be considered for distribution sections where its rated capacity and electrical configuration meet the project design.
Industrial and Public Infrastructure
Infrastructure projects may require transformer configurations for buildings, facilities and supporting electrical systems.
The selection process should consider load demand, installation space, environmental conditions, voltage regulation and applicable electrical standards.
For other capacities and voltage combinations, explore Hongweipower's Three-Phase Oil-Immersed Transformer Product Range.
IEC 60076 Standards and Technical Documentation
This 1250kVA transformer product is presented by Hongweipower Power with reference to IEC 60076.
For international procurement projects, buyers should confirm the applicable IEC 60076 parts, editions, technical requirements and acceptance criteria in the project specification.
CE conformity is a separate market compliance requirement and should not be treated as an IEC certification. Where CE marking or related conformity documentation is required for the destination market, the applicable product scope and supporting documents should be confirmed before order placement.
Customized Specifications for 1250kVA Three-Phase Oil-Immersed Transformer
Beyond the standard 1250kVA, 22kV/0.4kV configuration, Hongweipower Power customizes three-phase oil-immersed transformers from 30kVA to 10,000kVA, with 10kV, 20kV and 35kV as standard medium-voltage options and 60kV / 66kV on request.
1. Electrical Parameters
| Parameter |
Options |
| Rated Capacity |
30kVA–10,000kVA per unit |
| Voltage Level |
10kV / 20kV / 35kV; 60kV / 66kV on request |
| Voltage Ratio |
Customized to primary and secondary grid requirements |
| Frequency |
50Hz / 60Hz |
| Parallel Operation |
Supported |
| No-Load Loss (P0) |
10%–30% below applicable standard values |
| Load Loss (Pk) |
8%–25% below applicable standard values |
| Efficiency Level |
GB 20052-2020 Level 1 / Level 2 |
| Tap Changer |
DETC, or OLTC (evaluated per project) |
Loss reduction is achieved through upgraded core materials (amorphous alloy or high-permeability silicon steel), vacuum annealing, optimized winding cross-sections and electromagnetic simulation. Guaranteed loss values, tap positions and temperature-rise limits are confirmed in the approved technical datasheet.
2. Construction and Environment
| Item |
Options |
| Winding Material |
Copper / Aluminum |
| Cooling Method |
ONAN / ONAF / OFAF |
| Tank Structure |
Fully sealed / non-sealed; corrugated or customized |
| Dimensions and Radiators |
Customized to installation drawings and transport limits |
| Protection Accessories |
Pressure relief valve, gas relay, temperature indicators, monitoring devices |
| Environment |
Capability |
| High Altitude |
≥3,000m |
| High Humidity |
RH ≥95%, with anti-condensation design |
| Low Temperature |
Down to -40°C |
| Noise |
Target ≤55dB |
| Coastal / Industrial |
Salt-spray, dust and corrosion protection |
| Seismic |
Customized reinforcement |
3. Standards and Testing
- IEC 60076 series, with routine factory tests and test reports
- CE marking and conformity documentation for applicable products and markets
- Third-party inspection and re-inspection supported
Please confirm the applicable IEC parts and CE scope for your selected model before ordering.
4. OEM/ODM Services
Custom nameplates and branding, coating and appearance, packaging, project drawings and documentation, sample/prototype evaluation, and mass production to approved specifications.
For customized projects, we complete electromagnetic simulation and structural design within 72 hours, then provide a technical proposal covering losses, dimensions, weight and quotation.
5. Request a Proposal
Send us the following for engineering evaluation and a quotation:
- Capacity, voltage ratio and frequency
- Loss targets and efficiency level
- Winding material, cooling method and tap changer (DETC/OLTC)
- Temperature-rise limits, installation dimensions and site conditions
- Required IEC standards and CE documentation
Submit your datasheet, single-line diagram or project drawings via Power.
Transformer Manufacturing and Quality Control
Hongweipower Power's transformer manufacturing capabilities support the production of standard and customized power distribution equipment.
Manufacturing Background
| Company Information |
Published Data |
| Power Industry Experience |
21+ Years |
| Production Base |
20,000+ m² |
| Professional Team |
150+ People |
| Product Development |
Transformer R&D and customized engineering |
The manufacturing process covers several key operations.
Core Processing
Automatic core lamination and vacuum annealing are used in core component manufacturing to support magnetic performance and dimensional accuracy.
Coil Winding
CNC winding equipment is used to control conductor arrangement, winding quality and insulation wrapping.
Transformer Assembly
The core, windings and insulation components are assembled under controlled production conditions.
Vacuum Drying and Treatment
Oil-immersed transformer components undergo vacuum drying to support insulation performance before final assembly.
Final Assembly and Inspection
The tank, cooling system and protective devices are integrated before final inspection and delivery preparation.
Learn more about Power's Transformer Manufacturing Capabilities.
Frequently Asked Questions
1. What is the primary and secondary voltage of this 1250kVA transformer?
The listed model has a primary voltage of 22kV and a secondary voltage of 0.4kV. These ratings should be checked against the incoming medium-voltage network and downstream distribution system before order confirmation.
2. Is this 1250kVA transformer suitable for industrial distribution substations?
The product is listed for industrial plants, regional power stations, power distribution centers and distribution substations. Final suitability depends on the project's load demand, voltage system, protection design and installation conditions.
3. What is the difference between no-load loss and load loss?
No-load loss mainly comes from the transformer core and occurs when the transformer is energized. Load loss is mainly associated with winding resistance and changes with the operating current.
Both values should be specified and verified when evaluating transformer efficiency and long-term operating costs.
4. Can the 1250kVA transformer use copper or aluminum windings?
Hongweipower's three-phase oil-immersed transformer range offers copper and aluminum winding options according to the selected model and technical requirements. The required winding material should be confirmed before production.
5. Can the transformer be customized for different grid voltage requirements?
Yes. Hongweipower supports project-specific voltage ratios and tap-range adjustments. The primary and secondary voltage configuration should be provided during the inquiry so that the engineering team can evaluate the required design.
6. What cooling methods are available for this transformer range?
Hongweipower's three-phase oil-immersed transformer range identifies ONAN, ONAF and OFAN cooling configurations. The applicable cooling method for a 1250kVA project is selected according to the approved design and operating requirements.
7. What tests are performed before the transformer leaves the factory?
Hongweipower's published inspection process includes voltage ratio, connection group, no-load loss, load loss, insulation-related tests, temperature rise, tightness and dimensional inspections. The final test scope is defined by the product specification and agreed project requirements.